Working out how much power to contract is one of the easiest ways to cut your electricity bill in Spain without changing your habits. Contracted power (potencia contratada) is what you pay to be able to run several appliances at once, and it is charged every day whether you use electricity or not. Contract too much and you overpay every month; contract too little and the meter cuts the supply when you switch on the oven with the washing machine running.

Power (kW) and consumption (kWh) are not the same thing

Power is how much electricity you can draw at any one moment, in kW. Consumption is how much you use over time, in kWh. A washing machine may use less than 1 kWh per wash, but for the few minutes it spends heating the water it draws about 2 kW.

So the power you need has nothing to do with how much you use in a month. It depends on how many big appliances are on at the same time at the busiest moment of your day.

What each contracted kW costs in 2026

On the 2.0TD tariff you contract two power levels: one for the peak/standard period (P1), 8 am to midnight on working days, and one for off-peak (P2), midnight to 8 am plus all day at weekends and on national holidays.

According to the Ministry for the Ecological Transition, the 2026 tolls and charges in the power term add up to:

  • P1: €27.704413 per kW per year.
  • P2: €0.725423 per kW per year.

These come from the CNMC resolution of 18 December 2025 and Order TED/1524/2025. Your bill adds a supply margin, the electricity tax and VAT, so the final price per kW is a little higher.

The gap between the two periods is huge: almost all the cost is in P1. With the standard electricity tax and 21% VAT, each kW of P1 costs about €35 a year in tolls and charges alone. Each kW of P2 costs less than €1 a year.

How to work out how much power to contract

1. Check the rating of your big appliances

Every appliance states its maximum power on its rating plate or in the manual. As a rough guide:

Appliance Power at full load
Induction hob 2 to over 7 kW, depending on how many zones are on
Oven 2–3 kW
Washing machine and dishwasher (heating water) about 2 kW
Condenser tumble dryer 2–2.5 kW
Electric water heater (termo) 1.5–2 kW
Fan heater or electric radiator 2 kW
Air conditioning (home split unit) 1–2 kW
Electric car charger 2.3 kW on a normal socket, 3.7 or 7.4 kW with a wallbox

On top of that there is a background load of a few hundred watts: fridge, router, lights, TV.

2. Picture your busiest moment

Think of the time of day when the most things overlap. Say, dinner on a winter weekday:

  • Hob with two zones on high: 3 kW
  • Oven: 2 kW
  • Fan heater in the living room: 2 kW
  • Background load: 0.4 kW

Total: 7.4 kW. With 4.6 kW contracted, that combination trips the meter. But if the heater is not on while the oven is, you are at 5.4 kW, and if you use the microwave instead of the oven you drop below 4.6 kW.

The power you need depends as much on how you combine your appliances as on which ones you have.

3. Check your real peak demand

This is the most reliable step. Your smart meter records your maximum demand (potencia máxima demandada), and you can see it in your distributor’s customer area or on Datadis, the platform shared by Spain’s distributors. If your peak never gets close to your contracted power, you probably have more than you need.

Look at a whole year if you can: the months with heating or air conditioning are the ones that set the peak.

4. Choose P1 and P2 separately

With a smart meter you can contract any value in steps of 0.1 kW up to 15 kW (Royal Decree 88/2026, article 34.8). You no longer have to pick between the classic 3.45, 4.6 or 5.75 kW, which come from multiplying 230 V by the amps of the old limiter switches.

  • P1: match it to your real weekday peak with a small margin. This is the one that costs money.
  • P2: because it is so cheap, there is little point in skimping. It covers nights and also whole weekends, when people tend to cook more.

A worked example with real 2026 figures

A home with 5.75 kW in both P1 and P2 checks Datadis and finds its weekday peak never goes above 4 kW. It lowers P1 to 4.6 kW and, because it is going to charge an electric car overnight, raises P2 to 7.4 kW.

Change Tolls and charges per year With electricity tax and VAT
P1: 1.15 kW less −€31.86 about −€40.50
P2: 1.65 kW more +€1.20 about +€1.50

It saves about €39 a year and gets plenty of headroom to charge the car in the small hours. Had it raised P1 to 7.4 kW as well, it would have paid about €58 a year more in tolls and charges alone, tax included.

The catch with running everything in the cheapest hour

On the PVPC it makes sense to move the washing machine, dishwasher and water heater to the cheapest hours, which often fall overnight. Set all three to start at the same time, though, and for a while you are drawing 2 + 2 + 1.5 kW plus the background load: nearly 6 kW. With 4.6 kW in P2, the meter trips and you wake up to a half-finished wash.

There are two simple fixes:

  • Stagger the start times by half an hour to an hour. Washing machines and dishwashers only draw 2 kW while they heat the water at the start of the programme, so they just need to not start together. If you check each hour’s price on HoraLuz or on tomorrow’s prices, you will usually find two or three hours in a row that are almost equally cheap.
  • Raise your P2 power a little, which costs very little. If the cheap hours fall in the off-peak period (you can check the time bands), each extra kW of P2 costs less than €1 a year with tax.

An electric car is the same problem on a bigger scale: a 7.4 kW wallbox on its own is more than many homes have contracted. Most chargers let you cap the charging power, and how much it costs to charge an electric car shows which start time works out cheapest.

How to change your power and what to know first

  • You usually ask your supplier, who passes the request to the distributor. On the PVPC, it goes through your reference supplier.
  • Timing: the distributor has a maximum of 72 hours to apply it, or five working days if someone has to visit your home (RD 88/2026, article 38.6).
  • Only one change every 12 months: the distributor can turn down a new change if a year has not passed since the last one (article 38.3). If you go too low and keep tripping the meter, you may have to wait before raising it again. Lower it based on real data, not guesswork.
  • Lowering your power costs nothing beyond the distributor’s regulated fees (article 38.2). Ask how much they are before you request it.
  • Raising it counts as an additional connection and pays access fees for each extra kW and, if you go above what your supply point allows, extension fees too (RD 1048/2013, article 28). If your contract is more than 20 years old, the distributor must inspect the installation before granting it and may ask for a certificate from an electrician (boletín).
  • The PVPC only goes up to 10 kW. Above that you would have to move to a free-market tariff.

Lowering your power reduces the fixed part of every bill, but it does not change the price of each kWh. That depends on when you use electricity, which is what the PVPC hourly price shows.